Brochures
Installation, Operation, & Maintenance Manuals
Installation, Operation, & Maintenance Manuals
Frequently Asked Questions
GENERAL PROCESS
Who do I contact for warranty issues or replacement parts?
After shipment, parts can be purchased through the Service Department at info@climatecraft.com or by calling 405.415.9230 and asking for the Service Department. Warranty items can be addressed by the Quality Department. They can be contacted directly at info@climatecraft.com or by calling the 405.415.9230 and asking for the Quality Department.
Can I get a copy of the IOM manual?
A copy can be downloaded from our Downloads page.
How do I get drawings of lifting lug locations?
Contact the ClimateCraft Application Engineer who worked on your project or contact your local ClimateCraft representative.
Are standalone fan towers available to be ordered separately to replace fans in existing retrofit applications?
Yes, ClimateCraft has the knowledge to help make sure your electrical needs along with building access requirements are considered to ensure a smooth replacement.
How do I find out the ship date of my unit(s)?
Please contact your local ClimateCraft representative.
How can I get a spare parts list for my unit(s)/project?
Contact the ClimateCraft Application Engineer who worked on your project or contact your local ClimateCraft representative.
UNIT SPECIFIC
What insulation/wall thicknesses can you provide?
Our units have the option of either fiberglass insulation, which can be provided with polymer film wrap, or injected foam. Our insulation/wall panels can be provided in 2”, 3”, and 4” thicknesses.
What options do you have for your unit construction? Floor materials?
• Our units can be provided using galvanized, pre-paint galvanized, aluminum, stainless steel, or powder-coated exterior panels. Our interior panels can be galvanized, aluminum, 304 or 316 stainless steel, with solid or perforated liners. Our floor options include galvanized or stainless steel, aluminum or painted steel treadplate; we also offer a 2” water dam around all floor openings.
• Being a custom air handling unit manufacturer, we can design our units to fit your specified needs. If you have a material or specific gauge of material in mind, please contact us and we will advise if we are able to meet your unique requirements.
Do you offer knock down units for installation into tight spaces?
We offer true knock down capability, shipping the palletized wall and roof panels and components to meet tight jobsite constraints (see ACCESS™ site-assembled replacement units). We can also offer the flexibility of custom-designed shipping splits to minimize the size and weight of the assembled unit section and to reduce the amount of field labor required to reassemble units.
Can you factory mount control end devices by others?
Yes, we can wire mount control end devices provided to us from others. The devices will be terminated to a junction box for final field connection to the building system.
Do you offer electrical with single point power?
We can provide single point power distribution options for ease of installation.
Can you offer options for UV lights, indirect and direct fired gas heat, energy recovery wheels, heat pipes or plate exchangers?
Yes, we can provide the support necessary to meet your job specific air handling unit needs.
What does it mean when I see references to N+1, N-1 when dealing with fan arrays?
N+1 is the practice of having a spare fan to ensure system availability in the event of a main operating fan failure. When not needed, the N+1 fan is not utilized. N-1 is the practice of sizing your fan array so that if one fan fails, the other fans are sized to speed up and makeup for the lost fan performance. In this situation, all fans are being utilized at all times. Your redundancy comes from the existing fans being selected such that they can maintain the required CFM of your system even with a fan failure. For a detailed review of what is best for your application, contact your local ClimateCraft sales representative.
If you have any questions, please contact us.
Note: ClimateCraft’s fan array products allow for fans to be turned off for safety, repair, and maintenance purposes. ClimateCraft’s fan array products are not designed to turn individual fans on and off for the purpose of improving fan array efficiency, and ClimateCraft does not endorse turning individual fans on and off for the purpose of improving fan array efficiency. Any statement to the contrary is not supported by ClimateCraft.
Banners and Posters
BANNERS
BANNER PRINTING INSTRUCTIONS
(Included in .zip file for TIF/PDF)
Available File Formats for Download
TIF/PDF for Print
Zipped Files - 200dpi
CMYK Color Mode
JPG for Web and Presentations
Lg & Sm - 120 dpi
RGB Color Mode
POSTERS
POSTER PRINTING INSTRUCTIONS
(Included in .zip file for TIF/PDF)
Available File Formats for Download
TIF/PDF for Print
Zipped Files - 200dpi
CMYK Color Mode
JPG for Web and Presentations
Lg & Sm - 120 dpi
RGB Color Mode